Dual AC Wallbox2
The dual-wallbox charger is specially designed for high-traffic charging environments, including public rapid charging and fleet depots.
The dual-wallbox charger is specially designed for high-traffic charging environments, including public rapid charging and fleet depots.
• Flexible Configuration
–
– Multiple network connection with WiFi, LAN & 4G
– Provided with a 7 inch touch screen
– Optional with O-PEN module
– Optional with credit card payment terminal (Payter P66)
– Available in wall mount and pillar mount
Intelligent Control
– OCPP 1.6J communication protocol
– Local dynamic load management
– Device management system
– 2*MID energy meter
– Optional with ISO 15118-2 compliance, enabling advanced vehicle-charger communication for real-time monitoring and enhanced operational management
Safe & Reliable
– IP54 protection and steel cabinet, applicable for different environments
– Type A & 30mA leakage protection, optional with Type B RCD
Model |
|||
Model number |
LCNA-11DE-B LCNA-11DE-C |
LCNA-22DE-B LCNA-22DE-C |
|
Rated power |
2*11kW |
2*22kW |
|
Rated frequency |
50 / 60Hz | ||
Input Parameters |
|||
Input rated voltage |
AC400 / 415V |
||
Input rated current |
2*16A |
2*32A |
|
Output Parameters |
|||
Output voltage range |
AC340V~AC457V |
||
Output connector |
Case C: Type 2 cable (5m); Case B: Type 2 socket |
||
Protection |
|||
Leakage protection |
Type A+DC 6mA, optional with type B |
||
Output current range |
≤2*16A |
≤2*32A |
|
Electrical protection |
Over / under voltage protection, over load protection, short circuit protection, earth leakage protection, ground protection, over-temp protection, surge protection |
||
User Interface & Control |
|||
User authentification |
Plug and Charge, RFID Card or Mobile APP, optional with credit card payment terminal (payter P66) |
||
HMI |
7 inch |
||
Emergency stop |
Yes |
||
Connectivity |
WiFi / LAN / 4G / BLUETOOTH |
||
External communication |
RS485 |
||
Communication protocol |
OCPP 1.6J |
||
Metering |
2*MID energy meter |
||
Mechanical Parameters |
|||
Dimension (WxDxH) |
Charger: |
||
Weight |
Case B Charger: 20kg (net); 25kg (gross) Case C Charger: 25kg (net); 30kg (gross) Pillar: 30kg (net); 50kg (gross) |
||
Material |
Steel plate+plastic front cover (PC+ASA) |
||
IP & IK rating |
IP54; IK08 |
||
Environmental Data |
|||
Storage temperature |
-30~85°C |
||
Operating temperature |
-30~50℃ |
||
Operating humidity |
5%~95% RH (no condensation) |
||
Altitude |
≤2000m |
||
Cooling method |
Natural cooling |
||
Optional |
Type B RCD, payment terminal (Payter P66), ISO15118-2 communication, O-PEN, pillar |
||
Certificate |
CE, CB, UKCA, RoHS, REACH (available in Oct.2025) |